Water Treatment Engineers Test Kit (Photometer)
Test Kit for professionals for water treatment with photometric focus
- Mobile laboratory for water treatment monitoring
- Accurate & repeatable results for all types of industrial water systems
- Including photometer MD600 for professional photometric tests
- Ensure system performance & operating costs
The complete equipment for monitoring of closed circuits, evaporative cooling systems & boiler systems as routine tasks.
Ideal for prevention of most common problems and risks like corrosion, scale and biofouling or increased biological activity. The kit aditionally contains an MD600 Photometer for professional photometric water sample analysis.
N.º de encomenda 56K701400
Aplicações
- Água de Caldeira
- Água de Refrigeração
- Controle de Água de Piscina
- Controle de Desinfecção
- Galvanização
- Others
- Tratamento de Água Bruta
- Tratamento de Água Potável
- Tratamento de Esgotos
Informação sobre o produto
You need safe, fast and reliable test results? This Kit allows you to test your water system in your daily routine with visual methods, electrochemical instruments and additionally with an MD600 photometer for advances water analysis. This gives you the full overview and enables you to make the appropriate decisions on treatment programs.
Includes the following parameters: Conductivity, pH, glycol, aluminium, bromine, chlorine, copper, iron, molybdate and phosphate.
Parâmetros de teste | Faixa de Medição | Método No. | Método Químico |
---|---|---|---|
Alkalinity (P, M, OH) | 50 - 2400 mg/L CaCO3 | 56I700130 | |
Alumínio T | 0.01 - 0.3 mg/L Al | M40 | Eriochrom Cyanine R |
Bromo T | 0.05 - 13 mg/L Br2 | M80 | DPD |
Chloride | 20 - 12000 mg/L Cl- | 56I700190 | |
Cloro T | 0.01 - 6.0 mg/L Cl2 | M100 | DPD |
Cobre T | 0.05 - 5 mg/L Cu | M150 | Biquinoline |
Condutividade | 0 - 20 mS/cm | SD / Con | |
Dureza, total | 5 - 600 mg/L CaCO3 | 56I700280 | |
Dureza (Sim/Não) |
8 - 20 mg/L CaCO3 | Y/N | |
Ferro HR L | 0.1 - 10 mg/L Fe | M227 | Thioglycolate |
Ferro LR L (A) | 0.03 - 2 mg/L Fe | M225 | Ferrozine / Thioglycolate |
Fosfato HR T | 0.33 - 26 mg/L P | M321 | Vanadomolibdato |
Glicol | % PEG/MEG | Glycol/Refractometer | |
Hardness | 5 - 600 mg/L CaCO3 | 56I700270 | |
Hydrogen Peroxide | 15 - 500 mg/L H2O2 | 56I700290 | |
Molibdénio T | 1 - 50 mg/L MoO4 | M250 | Thioglycolate |
Nitrito |
10 - 2000 mg/L NaNO2 | 56I700300 | |
pH | 0 - 14 | SD / pH | |
Phosphonate | 0 - 20 mg/L HEDP | 56I700320 | |
Sulphite | 25 - 150 mg/L Na2SO3 | 56I700360 | |
Tannin | 50 - 300 mg/L Tannin | 56I700370 |
Título | Faixa de Medição | Método Químico | Unidade de Embalagem | Artigo No | Carrinho de cotação |
---|---|---|---|---|---|
KS138-TA4-4.5 Indicador | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013865 |
|
|
KS139-TA3 Alcalinidade LR Titrant | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013965 |
|
|
KS136-Alkaninity HR Titrant | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013665 |
|
|
Acidez / Alcalinidade P Indicador PA1 | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013565 |
|
|
KS137-Barium Solução Cloreto de Bário | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013765 |
|
|
KS142-CC2-Chloride LR Titrant | 20 - 12000 mg/L Cl- | 65 mL | 56L014265 |
|
|
KS141-BC2- Cloretos HR Titrant | 20 - 12000 mg/L Cl- | 65 mL | 56L014165 |
|
|
Indicador de cloreto BC1/CC1, 65 mL | 20 - 12000 mg/L Cl- | 65 mL | 56L714065 |
|
|
Tampão de dureza cálcica CH2 | 5 - 600 mg/L CaCO3 | 65 mL | 56L014465 |
|
|
KP216- CH1P - Indicador de dureza do cálcio | 5 - 600 mg/L CaCO3 | Pó / 20 g | 56P021620 |
|
|
KS162-TH3 Dureza LR Titrant 65 ml | 5 - 600 mg/L CaCO3 | 65 mL | 56L016265 |
|
|
KS145-H-TH3-CH3-CH3-Dureza HR Titrant 65 ml | 5 - 600 mg/L CaCO3 | 65 mL | 56L014565 |
|
|
TH1P/THIP Indicador de Dureza Total Pó 40g | 5 - 600 mg/L CaCO3 | Pó / 40 g | 56P028340 |
|
|
Total Tampão de Dureza TH2 | 5 - 600 mg/L CaCO3 | 65 mL | 56L016065 |
|
|
Dureza Sim/Não | 8 - 20 mg/L CaCO3 | Pastilhas / 100 | 515360BT |
|
|
Ferroin indicador N1 | 10 - 2000 mg/L NaNO2 | 65 mL | 56L017165 |
|
|
Nitrito Titrant N2 | 10 - 2000 mg/L NaNO2 | 65 mL | 56L017265 |
|
|
Phosphonate Neutraliser P1/2 | 0 - 20 mg/L HEDP | 65 mL | 56L070465 |
|
|
Phosphonate Indicator P4L | 0 - 20 mg/L HEDP | 65 mL | 56L017565 |
|
|
Phosphonate pH Adjuster P3 | 0 - 20 mg/L HEDP | 65 mL | 56L718365 |
|
|
KS176-P5 fosfonato titulante | 0 - 20 mg/L HEDP | 65 mL | 56L017665 |
|
|
KP186-S1-indicador de amido ácido | 25 - 150 mg/L Na2SO3 | Pó / 40 g | 56P018640 |
|
|
KS187-S2 Titulante de sulfito | 25 - 150 mg/L Na2SO3 | 65 mL | 56L018765 |
|
|
KP146-TN1-CL1P-TO3-CD4 Ácido sulfâmico | 50 - 300 mg/L Tannin | Pó / 50 g | 56P014650 |
|
|
Titante de Tanino TN2 | 50 - 300 mg/L Tannin | 65 mL | 56L019965 |
|
|
Tampão de Peróxido de Hidrogénio HP1 | 15 - 500 mg/L H2O2 | 65 mL | 56L041565 |
|
|
Peróxido de Hidrogénio HR Titrant HP2 | 15 - 500 mg/L H2O2 | 65 mL | 56L719965 |
|
|
Peróxido de Hidrogénio LR Titrant HP3 | 15 - 500 mg/L H2O2 | 65 mL | 56L649665 |
|
|
Alumínio Não. 1 | 0.01 - 0.3 mg/L Al | Eriochrom Cyanine R | Pastilhas / 100 | 515460BT |
|
Alumínio Não. 1 | 0.01 - 0.3 mg/L Al | Eriochrom Cyanine R | Pastilhas / 250 | 515461BT |
|
Alumínio Não. 2 | 0.01 - 0.3 mg/L Al | Eriochrom Cyanine R | Pastilhas / 100 | 515470BT |
|
Alumínio Não. 2 | 0.01 - 0.3 mg/L Al | Eriochrom Cyanine R | Pastilhas / 250 | 515471BT |
|
Set Alumínio No. 1/Não. 2 | 0.01 - 0.3 mg/L Al | Eriochrom Cyanine R | cada 100 | 517601BT |
|
Set Alumínio No. 1/Não. 2 | 0.01 - 0.3 mg/L Al | Eriochrom Cyanine R | cada 250 | 517602BT |
|
DPD Nº.1 | 0.05 - 13 mg/L Br2 | DPD | Pastilhas / 100 | 511050BT |
|
DPD Nº. 1 | 0.05 - 13 mg/L Br2 | DPD | Pastilhas / 250 | 511051BT |
|
DPD Nº. 1 | 0.05 - 13 mg/L Br2 | DPD | Pastilhas / 500 | 511052BT |
|
DPD Nº. 1 Alto Cálcio | 0.05 - 13 mg/L Br2 | DPD | Pastilhas / 100 | 515740BT |
|
DPD Nº. 1 Alto Cálcio | 0.05 - 13 mg/L Br2 | DPD | Pastilhas / 250 | 515741BT |
|
DPD Nº. 1 Alto Cálcio | 0.05 - 13 mg/L Br2 | DPD | Pastilhas / 500 | 515742BT |
|
DPD Nº. 3 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilhas / 100 | 511080BT |
|
DPD Nº. 3 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilhas / 250 | 511081BT |
|
DPD Nº. 3 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilhas / 500 | 511082BT |
|
DPD Nº. 3 Alto Cálcio | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilhas / 100 | 515730BT |
|
DPD Nº. 3 Alto Cálcio | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilhas / 250 | 515731BT |
|
DPD Nº. 3 Alto Cálcio | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilhas / 500 | 515732BT |
|
DPD Nº. 4 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilhas / 100 | 511220BT |
|
DPD Nº. 4 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilhas / 250 | 511221BT |
|
DPD Nº. 4 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilhas / 500 | 511222BT |
|
DPD Nº. 3 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilhas / 100 | 511420BT |
|
DPD Nº. 3 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilhas / 250 | 511421BT |
|
DPD Nº. 3 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilhas / 500 | 511422BT |
|
DPD Nº.4 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilhas / 100 | 511970BT |
|
DPD Nº. 4 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilhas / 250 | 511971BT |
|
DPD Nº. 4 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilhas / 500 | 511972BT |
|
Cobre Não. 1 | 0.05 - 5 mg/L Cua) | Biquinoline | Pastilhas / 100 | 513550BT |
|
Cobre Não. 1 | 0.05 - 5 mg/L Cua) | Biquinoline | Pastilhas / 250 | 513551BT |
|
Cobre Não. 2 | 0.05 - 5 mg/L Cua) | Biquinoline | Pastilhas / 100 | 513560BT |
|
Cobre Não. 2 | 0.05 - 5 mg/L Cua) | Biquinoline | Pastilhas / 250 | 513561BT |
|
Definir número de cobre 1/Não. 2 | 0.05 - 5 mg/L Cua) | Biquinoline | cada 100 | 517691BT |
|
Definir número de cobre 1/Não. 2 | 0.05 - 5 mg/L Cua) | Biquinoline | cada 250 | 517692BT |
|
ValidCheck Cobre 2 mg/l | 0.05 - 5 mg/L Cua) | Biquinoline | 1 pc. | 48141525 |
|
KP962-Amónio Persulfato de amónio em pó | 0.03 - 2 mg/L Fe | Ferrozine / Thioglycolate | Pó / 40 g | 56P096240 |
|
KS63-FE6 tioglicolato/molibdato HR RGT | 0.03 - 2 mg/L Fe | Ferrozine / Thioglycolate | 30 mL | 56L006330 |
|
KS63-FE6 tioglicolato/molibdato HR RGT | 0.03 - 2 mg/L Fe | Ferrozine / Thioglycolate | 65 mL | 56L006365 |
|
KS61-FE5-Ferrozina/Thioglicolato | 0.03 - 2 mg/L Fe | Ferrozine / Thioglycolate | 65 mL | 56L006165 |
|
Acidez / Alcalinidade P Indicador PA1 | 0.1 - 10 mg/L Fe | Thioglycolate | 30 mL | 56L013530 |
|
Tampão de dureza cálcica CH2 | 0.1 - 10 mg/L Fe | Thioglycolate | 5 x 65 mL mL | 56L014472 |
|
Iron HR Reagent Set | 0.1 - 10 mg/L Fe | Thioglycolate | 1 pc. | 56R023590 |
|
Molibdato HR Não. 1 | 1 - 50 mg/L MoO4 | Thioglycolate | Pastilhas / 100 | 513060BT |
|
Molibdato HR Não. 1 | 1 - 50 mg/L MoO4 | Thioglycolate | Pastilhas / 250 | 513061BT |
|
Molibdato HR Não. 2 | 1 - 50 mg/L MoO4 | Thioglycolate | Pastilhas / 100 | 513070BT |
|
Molibdato HR Não. 2 | 1 - 50 mg/L MoO4 | Thioglycolate | Pastilhas / 250 | 513071BT |
|
Definir nº Molibdato 1/Não. 2 | 1 - 50 mg/L MoO4 | Thioglycolate | cada 100 | 517631BT |
|
Definir nº Molibdato 1/Não. 2 | 1 - 50 mg/L MoO4 | Thioglycolate | cada 250 | 517632BT |
|
Definir nº fosfato 1 HR/No. 2 HR | 0.33 - 26 mg/L P | Vanadomolibdato | cada 100 | 517661BT |
|
Fosfatos HR P1 | 0.33 - 26 mg/L P | Vanadomolibdato | Pastilhas / 100 | 515810BT |
|
Fosfatos HR P2 | 0.33 - 26 mg/L P | Vanadomolibdato | Pastilhas / 100 | 515820BT |
|
Título | Artigo No | Carrinho de cotação |
---|---|---|
Seringa, plástico, 20 mL | 56A006501 |
|
Recipiente de titulação com tampa, plástico, 60 mL | 56A006701 |
|
Seringa de plástico, 5 mL | 56A008501 |
|
Tubo de ensaio 5/10 mL + CAP | 56A600401 |
|
Seringa de plástico 1 ml | 56A013501 |
|
ValidCheck Cloro 1,5 mg/l | 48105510 |
|
Refratómetro de glicol | 56M000401 |
|
- Plastic case
- SD40 Multi Pocket Tester
- MD610 Photometer
- 6 Cuvettes 24 mm round with lids & sealing rings
- DPD No.1 tablets BT
- DPD No.3 tablets
- Glycine tablets
- Nitrite tablets bottle
- Aluminium No.1 tablets
- Aluminium No.2 tablets
- Copper No.1 Test tablets
- Copper No.2 Test tablets
- Molybdate No.1 tablets
- Molybdate No.2 tablets
- Phosphate HR P1 tablets
- Phosphate HR P2 tablets
- Hardness Yes/No tablets
- Stirring rod and powder spoon
- pH Buffer 4 solution
- pH Buffer 7 solution
- pH Buffer 10 solution
- Chloride LR Titrant CC2
- Chloride HR Titrant BC2
- Tannin Indicator TN1
- Tannin Titrant TN2
- Acetic acid 20%
- Nitrite Titrant N2
- Phosphonate Titrant P5
- Peroxyacetic acid Buffer HP1
- Phosphonate Indicator P4L
- Nitrite Indicator N1
- Hydrogen Peroxide HR Titrant HP2
- Hydrogen Peroxide HR Titrant HP3
- Iron Reagent FE8
- Phosphonate pH Adjuster P3
- Chloride Indicator CC1
- Calcium Hardness Indicator CH1P
- Calcium Hardness Buffer CH2
- Phosphonate Neutraliser P1/2
- Sulphite Indicator S1
- Sulphite Titrant S2
- Alkalinity 4.5 Indicator TA4
- Alkalinity LR Titrant TA3
- Alkalinity HR Titrant PA2/TA2
- Alkalinity OH Reagent PA3
- Acidity/Alkalinity P Indicator PA1
- Hardness Total Buffer TH2
- Hardness Total Indicator TH1P
- Hardness LR Titrant TH3
- Hardness HR Titrant TH4
- 1413uS Standard Conductivity Solution
- Iron Reagent FE6
- Iron Reagent FE5
- Syringe plastic, 20 mL
- 2 Titration jars with cap, plastic, 60 mL
- Titration jar with cap, plastic, 250 mL
- Wash Bottle 250 mL
- Syringe Filter Holder 25 mm
- Filter Circles GF/C, 25 mm
- Filter Circle 0.45 μm, 25 mm
- Syringe, plastic, 1 mL
- 3 Wide neck bottles with lids, 250 mL
- Plastic tube with lid, 10 mL
- Glycol Refractometer, RHA-218ATC
- Screwdriver
- 4 AA Batteries
- Instruction manual