Water Treatment Engineers Test Kit (advanced)
Advanced test equipment for water treatment professionals
- All instruments & reagents for daily routine
- Including advanced photometer MD640 for additional parameters
- Early prevention & detection of risks
- Ensure system performance & operating costs
This kit contains pocket meters, checkit comparator, drop tests and MD640 photometer for advanced testing an extended range of control parameters.
Take the complete equipment for direct on-site analysis in practical case in one hand.
Advances analysis of all types of industrial water with visual, electrochemical and photometric methods.
Numéro d'ordre 56K701500
Applications
- Contrôle de la désinfection
- Contrôle de l’eau de la piscine
- Eau de chaudière
- Eau de refroidissement
- Galvanisation
- Others
- Traitement de l’eau brute
- Traitement de l’eau potable
- Traitement des eaux usées
Informations sur les produits
Water treatment engineers are engaged daily in the control of water quality in closed circuits, evaporative cooling systems and boiler systems. They need realiable equipment and accurate results to rely on. Both have an important impact on descions on treatment programs and optimal sytem performance
This Advanced Engineers Kit contains all you need to protect the life of the plant and operating costs. It allows early detection of corrosion, scale and biofouling and the investigation of increased biological activity.
Includes the following parameters: Conductivity, pH, glycol, aluminium, bromine, chlorine, copper, iron, molybdate, phosphate and alkalinity (M, P, OH).
Paramètres de test | Gamme de mesure | N° méthode | Méthode chimique |
---|---|---|---|
Alcalinité (P, M, OH) | 50 - 2400 mg/L CaCO3 | 56I700130 | |
Aluminium T | 0.01 - 0.3 mg/L Al | M40 | Eriochrome cyanine R |
Brome T | 0.05 - 13 mg/L Br2 | M80 | DPD |
Chlore T | 0.01 - 6.0 mg/L Cl2 | M100 | DPD |
Chloride | 20 - 12000 mg/L Cl- | 56I700190 | |
Conductivity | 0 - 200 mS/cm | SD 335 | |
Cuivre T | 0.05 - 5 mg/L Cu | M150 | Biquinoline |
Dureté, totale | 5 - 600 mg/L CaCO3 | 56I700280 | |
Dureté (Oui/Non) |
8 - 20 mg/L CaCO3 | Y/N | |
Fer HR L | 0.1 - 10 mg/L Fe | M227 | Thioglycolate |
Fer LR L (A) | 0.03 - 2 mg/L Fe | M225 | Ferrozine / Thioglycolate |
Glycol | % PEG/MEG | Glycol/Refractometer | |
Hardness Calcium | 5 - 600 mg/L CaCO3 | 56I700270 | |
Molybdate T | 1 - 50 mg/L MoO4 | M250 | Thioglycolate |
Nitrite |
10 - 2000 mg/L NaNO2 | 56I700300 | |
Peroxyde d’hydrogène | 15 - 500 mg/L H2O2 | 56I700290 | |
pH | -2 - 16 | ||
Phosphate HR T | 0.33 - 26 mg/L P | M321 | Vanadomolybdate |
Phosphonate | 0 - 20 mg/L HEDP | 56I700320 | |
PTSA 2P | 10 - 400 ppb | M501 | Fluorescence |
Sulphite | 25 - 150 mg/L Na2SO3 | 56I700360 | |
Tanin | 50 - 300 mg/L Tannin | 56I700370 |
Titre | Gamme de mesure | Méthode chimique | Pack contenant | Code | Ajouter au panier de citations |
---|---|---|---|---|---|
KS138-TA4-Indicateur 4,5 | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013865 |
|
|
KS139-TA3-Titrant alcalinité LR | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013965 |
|
|
KS136-Titrant alcalinité HR | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013665 |
|
|
Acidité / Alcalinité P Indicateur PA1 | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013565 |
|
|
KS137-Solution chlorure de baryum | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013765 |
|
|
KS142-CC2-Titrant chlorure LR | 20 - 12000 mg/L Cl- | 65 mL | 56L014265 |
|
|
KS141-BC2-Titrant chlorure HR | 20 - 12000 mg/L Cl- | 65 mL | 56L014165 |
|
|
Indicateur de chlorure BC1/CC1, 65 mL | 20 - 12000 mg/L Cl- | 65 mL | 56L714065 |
|
|
Dureté du calcium tampon CH2 | 5 - 600 mg/L CaCO3 | 65 mL | 56L014465 |
|
|
KP216- CH1P-indicateur dureté calcique | 5 - 600 mg/L CaCO3 | Poudre / 20 g | 56P021620 |
|
|
KS162-TH3-Titrant dureté LR 65 ml | 5 - 600 mg/L CaCO3 | 65 mL | 56L016265 |
|
|
KS145-H-TH3-CH3-Titrant dureté HR 65 ml | 5 - 600 mg/L CaCO3 | 65 mL | 56L014565 |
|
|
Hardness Total Indicator TH1P | 5 - 600 mg/L CaCO3 | Poudre / 40 g | 56P028340 |
|
|
Tampon dureté totale TH2 | 5 - 600 mg/L CaCO3 | 65 mL | 56L016065 |
|
|
Dureté oui/non | 8 - 20 mg/L CaCO3 | Pastilles / 100 | 515360BT |
|
|
Indicateur ferrozine N1 | 10 - 2000 mg/L NaNO2 | 65 mL | 56L017165 |
|
|
Nitrite Titrant N2 | 10 - 2000 mg/L NaNO2 | 65 mL | 56L017265 |
|
|
Phosphonate Neutraliser P1/2 | 0 - 20 mg/L HEDP | 65 mL | 56L070465 |
|
|
Phosphonate Indicator P4L | 0 - 20 mg/L HEDP | 65 mL | 56L017565 |
|
|
Phosphonate pH Adjuster P3 | 0 - 20 mg/L HEDP | 65 mL | 56L718365 |
|
|
KS176-P5-Titrant phosphanate | 0 - 20 mg/L HEDP | 65 mL | 56L017665 |
|
|
KP186-S1 Indicateur acide/amidon | 25 - 150 mg/L Na2SO3 | Poudre / 40 g | 56P018640 |
|
|
KS187-S2-Titrant sulfite | 25 - 150 mg/L Na2SO3 | 65 mL | 56L018765 |
|
|
KP146-TN1-CL1P-TO3-CD4-Acide sulfamique | 50 - 300 mg/L Tannin | Poudre / 50 g | 56P014650 |
|
|
Titrant de tanin TN2 | 50 - 300 mg/L Tannin | 65 mL | 56L019965 |
|
|
Tampon peroxyde d’hydrogène HP1 | 15 - 500 mg/L H2O2 | 65 mL | 56L041565 |
|
|
Peroxyde d’hydrogène HR Titrant HP2 | 15 - 500 mg/L H2O2 | 65 mL | 56L719965 |
|
|
Peroxyde d’hydrogène LR Titrant HP3 | 15 - 500 mg/L H2O2 | 65 mL | 56L649665 |
|
|
Aluminium N° 1 | 0.01 - 0.3 mg/L Al | Eriochrome cyanine R | Pastilles / 100 | 515460BT |
|
Aluminium N° 1 | 0.01 - 0.3 mg/L Al | Eriochrome cyanine R | Pastilles / 250 | 515461BT |
|
Aluminium N° 2 | 0.01 - 0.3 mg/L Al | Eriochrome cyanine R | Pastilles / 100 | 515470BT |
|
Aluminium N° 2 | 0.01 - 0.3 mg/L Al | Eriochrome cyanine R | Pastilles / 250 | 515471BT |
|
Kit aluminium N° 1/N° 2 | 0.01 - 0.3 mg/L Al | Eriochrome cyanine R | 100 chacun | 517601BT |
|
Kit aluminium N° 1/N° 2 | 0.01 - 0.3 mg/L Al | Eriochrome cyanine R | 250 chacun | 517602BT |
|
DPD N°1 | 0.05 - 13 mg/L Br2 | DPD | Pastilles / 100 | 511050BT |
|
DPD N° 1 | 0.05 - 13 mg/L Br2 | DPD | Pastilles / 250 | 511051BT |
|
DPD N° 1 | 0.05 - 13 mg/L Br2 | DPD | Pastilles / 500 | 511052BT |
|
DPD N° 1 High Calcium | 0.05 - 13 mg/L Br2 | DPD | Pastilles / 100 | 515740BT |
|
DPD N° 1 High Calcium | 0.05 - 13 mg/L Br2 | DPD | Pastilles / 250 | 515741BT |
|
DPD N° 1 High Calcium | 0.05 - 13 mg/L Br2 | DPD | Pastilles / 500 | 515742BT |
|
DPD N° 3 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 100 | 511080BT |
|
DPD N° 3 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 250 | 511081BT |
|
DPD N° 3 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 500 | 511082BT |
|
DPD N° 3 High Calcium | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 100 | 515730BT |
|
DPD N° 3 High Calcium | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 250 | 515731BT |
|
DPD N° 3 High Calcium | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 500 | 515732BT |
|
DPD N° 4 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 100 | 511220BT |
|
DPD N° 4 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 250 | 511221BT |
|
DPD N° 4 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 500 | 511222BT |
|
DPD N° 3 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 100 | 511420BT |
|
DPD N° 3 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 250 | 511421BT |
|
DPD N° 3 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 500 | 511422BT |
|
DPD N°4 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 100 | 511970BT |
|
DPD N° 4 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 250 | 511971BT |
|
DPD N° 4 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 500 | 511972BT |
|
Cuivre N° 1 | 0.05 - 5 mg/L Cua) | Biquinoline | Pastilles / 100 | 513550BT |
|
Cuivre N° 1 | 0.05 - 5 mg/L Cua) | Biquinoline | Pastilles / 250 | 513551BT |
|
Cuivre N° 2 | 0.05 - 5 mg/L Cua) | Biquinoline | Pastilles / 100 | 513560BT |
|
Cuivre N° 2 | 0.05 - 5 mg/L Cua) | Biquinoline | Pastilles / 250 | 513561BT |
|
Kit cuivre N° 1/N° 2 | 0.05 - 5 mg/L Cua) | Biquinoline | 100 chacun | 517691BT |
|
Kit cuivre N° 1/N° 2 | 0.05 - 5 mg/L Cua) | Biquinoline | 250 chacun | 517692BT |
|
ValidCheck Cuivre 2 mg/l | 0.05 - 5 mg/L Cua) | Biquinoline | 1 Pièces | 48141525 |
|
KP962 Poudre persulphate d’ammonium | 0.03 - 2 mg/L Fe | Ferrozine / Thioglycolate | Poudre / 40 g | 56P096240 |
|
KS63-FE6-Thioglycolate/Molybdate HR RGT | 0.03 - 2 mg/L Fe | Ferrozine / Thioglycolate | 30 mL | 56L006330 |
|
KS63-FE6-Thioglycolate/Molybdate HR RGT | 0.03 - 2 mg/L Fe | Ferrozine / Thioglycolate | 65 mL | 56L006365 |
|
KS61-FE5-Ferrozine/Thioglycolate | 0.03 - 2 mg/L Fe | Ferrozine / Thioglycolate | 65 mL | 56L006165 |
|
Acidité / Alcalinité P Indicateur PA1 | 0.1 - 10 mg/L Fe | Thioglycolate | 30 mL | 56L013530 |
|
Dureté du calcium tampon CH2 | 0.1 - 10 mg/L Fe | Thioglycolate | 5 x 65 mL mL | 56L014472 |
|
Iron HR Reagent Set | 0.1 - 10 mg/L Fe | Thioglycolate | 1 Pièces | 56R023590 |
|
Molybdate HR N° 1 | 1 - 50 mg/L MoO4 | Thioglycolate | Pastilles / 100 | 513060BT |
|
Molybdate HR N° 1 | 1 - 50 mg/L MoO4 | Thioglycolate | Pastilles / 250 | 513061BT |
|
Molybdate HR N° 2 | 1 - 50 mg/L MoO4 | Thioglycolate | Pastilles / 100 | 513070BT |
|
Molybdate HR N° 2 | 1 - 50 mg/L MoO4 | Thioglycolate | Pastilles / 250 | 513071BT |
|
Kit molybdate N° 1/N° 2 | 1 - 50 mg/L MoO4 | Thioglycolate | 100 chacun | 517631BT |
|
Kit molybdate N° 1/N° 2 | 1 - 50 mg/L MoO4 | Thioglycolate | 250 chacun | 517632BT |
|
Kit phosphate N° 1 HR/N° 2 HR | 0.33 - 26 mg/L P | Vanadomolybdate | 100 chacun | 517661BT |
|
Phosphate HR P1 | 0.33 - 26 mg/L P | Vanadomolybdate | Pastilles / 100 | 515810BT |
|
Phosphate HR P2 | 0.33 - 26 mg/L P | Vanadomolybdate | Pastilles / 100 | 515820BT |
|
Solution ajoutée pour étalon PTSA, 1000 ppb | 10 - 400 ppb | Fluorescence | 1 Pièces | 461210 |
|
Titre | Code | Ajouter au panier de citations |
---|---|---|
Seringue, plastique, 20 mL | 56A006501 |
|
Récipient de titrage avec couvercle, plastique, 60 mL | 56A006701 |
|
Seringue en plastique, 5 mL | 56A008501 |
|
Tube de test 5/10 mL + capuchon | 56A600401 |
|
Seringue en plastique, 1 ml | 56A013501 |
|
LC 12 pour SD 320 / SD 325 Con, jusqu’à 200 mS/cm | 19805040 |
|
ValidCheck Chlore 1,5 mg/l | 48105510 |
|
SD 335 Multi (appareil de base) | 724830 |
|
Refractomètre Glycol | 56M000401 |
|
- Plastic case
- 6 Cuvettes 24 mm round with lids & sealing rings
- SD 335 Multi
- MD640 Photometer
- Brush, 11 cm length
- DPD No.1 tablets BT
- DPD No.3 tablets
- Glycine tablets
- DPD Nitrite tablets bottle
- Aluminium No.1 tablets
- Aluminium No.2 tablets
- Copper No.1 Test tablets
- Copper No.2 Test tablets
- Molybdate No.1 tablets
- Molybdate No.2 tablets
- Phosphate H.R.P1 tablets
- Phosphate H.R.P2 tablets
- Copper/Zinc L.R.Test Tablets
- Hardness Yes/No tablets
- pH Buffer 4 solution
- pH Buffer 7 solution
- pH Buffer 10 solution
- 1413uS Standard Conductivity Solution
- Iron Reagent FE6
- Iron Reagent FE5
- Alkalinity 4.5 Indicator TA4
- Alkalinity LR Titrant TA3
- Alkalinity HR Titrant PA2/TA2
- Alkalinity OH Reagent
- Hardness Total Buffer TH2
- Hardness Total Indicator TH1P
- Hardness LR Titrant TH3
- Hardness HR Titrant TH4
- Chloride LR Titrant CC2
- Chloride HR Titrant BC2
- Tannin Indicator TN1
- Tannin Titrant TN2
- Acetic acid 20%
- Nitrite Titrant N2
- Phosphonate Titrant P5
- Hydrogen Peroxide Buffer HP1
- Phosphonate Indicator P4L
- Nitrite Indicator N1
- Hydrogen Peroxide HR Titrant HP2
- Iron Reagent FE8
- Phosphonate pH Adjuster P3
- Chloride Indicator CC1
- Calcium Hardness Indicator CH1P
- Calcium Hardness Buffer CH2
- Phosphonate Neutraliser P1/2
- Sulphite Indicator S1
- Sulphite Indicator S2
- Syringe plastic, 20 mL
- 2 Titration jars with cap, plastic, 60 mL
- Titration jar with cap, plastic, 250 mL
- Wash Bottle 250 mL
- Syringe Filter Holder 25 mm
- Filter Circles GF/C, 25 mm
- Filter Circle 0.45 μm, 25 mm
- Syringe, plastic, 1 mL
- Stirring rod and powder spoon
- Wide neck bottle with lid, 250 mL
- Glycol Refractometer, RHA-218ATC
- Instruction manual