Water Treatment Engineers Test Kit (Photometer)
Test Kit for professionals for water treatment with photometric focus
- Mobile laboratory for water treatment monitoring
- Accurate & repeatable results for all types of industrial water systems
- Including photometer MD600 for professional photometric tests
- Ensure system performance & operating costs
The complete equipment for monitoring of closed circuits, evaporative cooling systems & boiler systems as routine tasks.
Ideal for prevention of most common problems and risks like corrosion, scale and biofouling or increased biological activity. The kit aditionally contains an MD600 Photometer for professional photometric water sample analysis.
Numéro d'ordre 56K701400
Applications
- Contrôle de la désinfection
- Contrôle de l’eau de la piscine
- Eau de chaudière
- Eau de refroidissement
- Galvanisation
- Others
- Traitement de l’eau brute
- Traitement de l’eau potable
- Traitement des eaux usées
Informations sur les produits
You need safe, fast and reliable test results? This Kit allows you to test your water system in your daily routine with visual methods, electrochemical instruments and additionally with an MD600 photometer for advances water analysis. This gives you the full overview and enables you to make the appropriate decisions on treatment programs.
Includes the following parameters: Conductivity, pH, glycol, aluminium, bromine, chlorine, copper, iron, molybdate and phosphate.
Paramètres de test | Gamme de mesure | N° méthode | Méthode chimique |
---|---|---|---|
Alcalinité (P, M, OH) | 50 - 2400 mg/L CaCO3 | 56I700130 | |
Aluminium T | 0.01 - 0.3 mg/L Al | M40 | Eriochrome cyanine R |
Brome T | 0.05 - 13 mg/L Br2 | M80 | DPD |
Chlore T | 0.01 - 6.0 mg/L Cl2 | M100 | DPD |
Chloride | 20 - 12000 mg/L Cl- | 56I700190 | |
Conductivity | 0 - 20 mS/cm | SD / Con | |
Cuivre T | 0.05 - 5 mg/L Cu | M150 | Biquinoline |
Dureté, totale | 5 - 600 mg/L CaCO3 | 56I700280 | |
Dureté (Oui/Non) |
8 - 20 mg/L CaCO3 | Y/N | |
Fer HR L | 0.1 - 10 mg/L Fe | M227 | Thioglycolate |
Fer LR L (A) | 0.03 - 2 mg/L Fe | M225 | Ferrozine / Thioglycolate |
Glycol | % PEG/MEG | Glycol/Refractometer | |
Hardness Calcium | 5 - 600 mg/L CaCO3 | 56I700270 | |
Molybdate T | 1 - 50 mg/L MoO4 | M250 | Thioglycolate |
Nitrite |
10 - 2000 mg/L NaNO2 | 56I700300 | |
Peroxyde d’hydrogène | 15 - 500 mg/L H2O2 | 56I700290 | |
pH | 0 - 14 | SD / pH | |
Phosphate HR T | 0.33 - 26 mg/L P | M321 | Vanadomolybdate |
Phosphonate | 0 - 20 mg/L HEDP | 56I700320 | |
Sulphite | 25 - 150 mg/L Na2SO3 | 56I700360 | |
Tanin | 50 - 300 mg/L Tannin | 56I700370 |
Titre | Gamme de mesure | Méthode chimique | Pack contenant | Code | Ajouter au panier de citations |
---|---|---|---|---|---|
KS138-TA4-Indicateur 4,5 | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013865 |
|
|
KS139-TA3-Titrant alcalinité LR | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013965 |
|
|
KS136-Titrant alcalinité HR | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013665 |
|
|
Acidité / Alcalinité P Indicateur PA1 | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013565 |
|
|
KS137-Solution chlorure de baryum | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013765 |
|
|
KS142-CC2-Titrant chlorure LR | 20 - 12000 mg/L Cl- | 65 mL | 56L014265 |
|
|
KS141-BC2-Titrant chlorure HR | 20 - 12000 mg/L Cl- | 65 mL | 56L014165 |
|
|
Indicateur de chlorure BC1/CC1, 65 mL | 20 - 12000 mg/L Cl- | 65 mL | 56L714065 |
|
|
Dureté du calcium tampon CH2 | 5 - 600 mg/L CaCO3 | 65 mL | 56L014465 |
|
|
KP216- CH1P-indicateur dureté calcique | 5 - 600 mg/L CaCO3 | Poudre / 20 g | 56P021620 |
|
|
KS162-TH3-Titrant dureté LR 65 ml | 5 - 600 mg/L CaCO3 | 65 mL | 56L016265 |
|
|
KS145-H-TH3-CH3-Titrant dureté HR 65 ml | 5 - 600 mg/L CaCO3 | 65 mL | 56L014565 |
|
|
Hardness Total Indicator TH1P | 5 - 600 mg/L CaCO3 | Poudre / 40 g | 56P028340 |
|
|
Tampon dureté totale TH2 | 5 - 600 mg/L CaCO3 | 65 mL | 56L016065 |
|
|
Dureté oui/non | 8 - 20 mg/L CaCO3 | Pastilles / 100 | 515360BT |
|
|
Indicateur ferrozine N1 | 10 - 2000 mg/L NaNO2 | 65 mL | 56L017165 |
|
|
Nitrite Titrant N2 | 10 - 2000 mg/L NaNO2 | 65 mL | 56L017265 |
|
|
Phosphonate Neutraliser P1/2 | 0 - 20 mg/L HEDP | 65 mL | 56L070465 |
|
|
Phosphonate Indicator P4L | 0 - 20 mg/L HEDP | 65 mL | 56L017565 |
|
|
Phosphonate pH Adjuster P3 | 0 - 20 mg/L HEDP | 65 mL | 56L718365 |
|
|
KS176-P5-Titrant phosphanate | 0 - 20 mg/L HEDP | 65 mL | 56L017665 |
|
|
KP186-S1 Indicateur acide/amidon | 25 - 150 mg/L Na2SO3 | Poudre / 40 g | 56P018640 |
|
|
KS187-S2-Titrant sulfite | 25 - 150 mg/L Na2SO3 | 65 mL | 56L018765 |
|
|
KP146-TN1-CL1P-TO3-CD4-Acide sulfamique | 50 - 300 mg/L Tannin | Poudre / 50 g | 56P014650 |
|
|
Titrant de tanin TN2 | 50 - 300 mg/L Tannin | 65 mL | 56L019965 |
|
|
Tampon peroxyde d’hydrogène HP1 | 15 - 500 mg/L H2O2 | 65 mL | 56L041565 |
|
|
Peroxyde d’hydrogène HR Titrant HP2 | 15 - 500 mg/L H2O2 | 65 mL | 56L719965 |
|
|
Peroxyde d’hydrogène LR Titrant HP3 | 15 - 500 mg/L H2O2 | 65 mL | 56L649665 |
|
|
Aluminium N° 1 | 0.01 - 0.3 mg/L Al | Eriochrome cyanine R | Pastilles / 100 | 515460BT |
|
Aluminium N° 1 | 0.01 - 0.3 mg/L Al | Eriochrome cyanine R | Pastilles / 250 | 515461BT |
|
Aluminium N° 2 | 0.01 - 0.3 mg/L Al | Eriochrome cyanine R | Pastilles / 100 | 515470BT |
|
Aluminium N° 2 | 0.01 - 0.3 mg/L Al | Eriochrome cyanine R | Pastilles / 250 | 515471BT |
|
Kit aluminium N° 1/N° 2 | 0.01 - 0.3 mg/L Al | Eriochrome cyanine R | 100 chacun | 517601BT |
|
Kit aluminium N° 1/N° 2 | 0.01 - 0.3 mg/L Al | Eriochrome cyanine R | 250 chacun | 517602BT |
|
DPD N°1 | 0.05 - 13 mg/L Br2 | DPD | Pastilles / 100 | 511050BT |
|
DPD N° 1 | 0.05 - 13 mg/L Br2 | DPD | Pastilles / 250 | 511051BT |
|
DPD N° 1 | 0.05 - 13 mg/L Br2 | DPD | Pastilles / 500 | 511052BT |
|
DPD N° 1 High Calcium | 0.05 - 13 mg/L Br2 | DPD | Pastilles / 100 | 515740BT |
|
DPD N° 1 High Calcium | 0.05 - 13 mg/L Br2 | DPD | Pastilles / 250 | 515741BT |
|
DPD N° 1 High Calcium | 0.05 - 13 mg/L Br2 | DPD | Pastilles / 500 | 515742BT |
|
DPD N° 3 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 100 | 511080BT |
|
DPD N° 3 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 250 | 511081BT |
|
DPD N° 3 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 500 | 511082BT |
|
DPD N° 3 High Calcium | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 100 | 515730BT |
|
DPD N° 3 High Calcium | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 250 | 515731BT |
|
DPD N° 3 High Calcium | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 500 | 515732BT |
|
DPD N° 4 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 100 | 511220BT |
|
DPD N° 4 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 250 | 511221BT |
|
DPD N° 4 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 500 | 511222BT |
|
DPD N° 3 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 100 | 511420BT |
|
DPD N° 3 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 250 | 511421BT |
|
DPD N° 3 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 500 | 511422BT |
|
DPD N°4 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 100 | 511970BT |
|
DPD N° 4 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 250 | 511971BT |
|
DPD N° 4 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Pastilles / 500 | 511972BT |
|
Cuivre N° 1 | 0.05 - 5 mg/L Cua) | Biquinoline | Pastilles / 100 | 513550BT |
|
Cuivre N° 1 | 0.05 - 5 mg/L Cua) | Biquinoline | Pastilles / 250 | 513551BT |
|
Cuivre N° 2 | 0.05 - 5 mg/L Cua) | Biquinoline | Pastilles / 100 | 513560BT |
|
Cuivre N° 2 | 0.05 - 5 mg/L Cua) | Biquinoline | Pastilles / 250 | 513561BT |
|
Kit cuivre N° 1/N° 2 | 0.05 - 5 mg/L Cua) | Biquinoline | 100 chacun | 517691BT |
|
Kit cuivre N° 1/N° 2 | 0.05 - 5 mg/L Cua) | Biquinoline | 250 chacun | 517692BT |
|
ValidCheck Cuivre 2 mg/l | 0.05 - 5 mg/L Cua) | Biquinoline | 1 Pièces | 48141525 |
|
KP962 Poudre persulphate d’ammonium | 0.03 - 2 mg/L Fe | Ferrozine / Thioglycolate | Poudre / 40 g | 56P096240 |
|
KS63-FE6-Thioglycolate/Molybdate HR RGT | 0.03 - 2 mg/L Fe | Ferrozine / Thioglycolate | 30 mL | 56L006330 |
|
KS63-FE6-Thioglycolate/Molybdate HR RGT | 0.03 - 2 mg/L Fe | Ferrozine / Thioglycolate | 65 mL | 56L006365 |
|
KS61-FE5-Ferrozine/Thioglycolate | 0.03 - 2 mg/L Fe | Ferrozine / Thioglycolate | 65 mL | 56L006165 |
|
Acidité / Alcalinité P Indicateur PA1 | 0.1 - 10 mg/L Fe | Thioglycolate | 30 mL | 56L013530 |
|
Dureté du calcium tampon CH2 | 0.1 - 10 mg/L Fe | Thioglycolate | 5 x 65 mL mL | 56L014472 |
|
Iron HR Reagent Set | 0.1 - 10 mg/L Fe | Thioglycolate | 1 Pièces | 56R023590 |
|
Molybdate HR N° 1 | 1 - 50 mg/L MoO4 | Thioglycolate | Pastilles / 100 | 513060BT |
|
Molybdate HR N° 1 | 1 - 50 mg/L MoO4 | Thioglycolate | Pastilles / 250 | 513061BT |
|
Molybdate HR N° 2 | 1 - 50 mg/L MoO4 | Thioglycolate | Pastilles / 100 | 513070BT |
|
Molybdate HR N° 2 | 1 - 50 mg/L MoO4 | Thioglycolate | Pastilles / 250 | 513071BT |
|
Kit molybdate N° 1/N° 2 | 1 - 50 mg/L MoO4 | Thioglycolate | 100 chacun | 517631BT |
|
Kit molybdate N° 1/N° 2 | 1 - 50 mg/L MoO4 | Thioglycolate | 250 chacun | 517632BT |
|
Kit phosphate N° 1 HR/N° 2 HR | 0.33 - 26 mg/L P | Vanadomolybdate | 100 chacun | 517661BT |
|
Phosphate HR P1 | 0.33 - 26 mg/L P | Vanadomolybdate | Pastilles / 100 | 515810BT |
|
Phosphate HR P2 | 0.33 - 26 mg/L P | Vanadomolybdate | Pastilles / 100 | 515820BT |
|
Titre | Code | Ajouter au panier de citations |
---|---|---|
Seringue, plastique, 20 mL | 56A006501 |
|
Récipient de titrage avec couvercle, plastique, 60 mL | 56A006701 |
|
Seringue en plastique, 5 mL | 56A008501 |
|
Tube de test 5/10 mL + capuchon | 56A600401 |
|
Seringue en plastique, 1 ml | 56A013501 |
|
ValidCheck Chlore 1,5 mg/l | 48105510 |
|
Refractomètre Glycol | 56M000401 |
|
- Plastic case
- SD40 Multi Pocket Tester
- MD610 Photometer
- 6 Cuvettes 24 mm round with lids & sealing rings
- DPD No.1 tablets BT
- DPD No.3 tablets
- Glycine tablets
- Nitrite tablets bottle
- Aluminium No.1 tablets
- Aluminium No.2 tablets
- Copper No.1 Test tablets
- Copper No.2 Test tablets
- Molybdate No.1 tablets
- Molybdate No.2 tablets
- Phosphate HR P1 tablets
- Phosphate HR P2 tablets
- Hardness Yes/No tablets
- Stirring rod and powder spoon
- pH Buffer 4 solution
- pH Buffer 7 solution
- pH Buffer 10 solution
- Chloride LR Titrant CC2
- Chloride HR Titrant BC2
- Tannin Indicator TN1
- Tannin Titrant TN2
- Acetic acid 20%
- Nitrite Titrant N2
- Phosphonate Titrant P5
- Peroxyacetic acid Buffer HP1
- Phosphonate Indicator P4L
- Nitrite Indicator N1
- Hydrogen Peroxide HR Titrant HP2
- Hydrogen Peroxide HR Titrant HP3
- Iron Reagent FE8
- Phosphonate pH Adjuster P3
- Chloride Indicator CC1
- Calcium Hardness Indicator CH1P
- Calcium Hardness Buffer CH2
- Phosphonate Neutraliser P1/2
- Sulphite Indicator S1
- Sulphite Titrant S2
- Alkalinity 4.5 Indicator TA4
- Alkalinity LR Titrant TA3
- Alkalinity HR Titrant PA2/TA2
- Alkalinity OH Reagent PA3
- Acidity/Alkalinity P Indicator PA1
- Hardness Total Buffer TH2
- Hardness Total Indicator TH1P
- Hardness LR Titrant TH3
- Hardness HR Titrant TH4
- 1413uS Standard Conductivity Solution
- Iron Reagent FE6
- Iron Reagent FE5
- Syringe plastic, 20 mL
- 2 Titration jars with cap, plastic, 60 mL
- Titration jar with cap, plastic, 250 mL
- Wash Bottle 250 mL
- Syringe Filter Holder 25 mm
- Filter Circles GF/C, 25 mm
- Filter Circle 0.45 μm, 25 mm
- Syringe, plastic, 1 mL
- 3 Wide neck bottles with lids, 250 mL
- Plastic tube with lid, 10 mL
- Glycol Refractometer, RHA-218ATC
- Screwdriver
- 4 AA Batteries
- Instruction manual
- Declaration of warranty